| Item项目 | Content详细内容 | Criterion标准 | Remarks备注 | |
| Over charge protect过充保护 | Over charge detection voltage(Cell) 单体过充保护电压 | 3.700V±0.050V | ||
| Protect delay time 保护延迟时间 | 500ms—1500ms | |||
| Over charge release voltage(Cell) 单体过充解除电压 | 3.500V±0.050V | |||
| Over discharge protect过放保护 | Over discharge detection voltage(Cell) 单体过放保护电压 | 2.300V±0.050V | ||
| Protect delay time 保护延迟时间 | 500ms—1500ms | |||
| Over discharge release voltage(Cell) 单体过放解除电压 | / | 充电恢复 | ||
| Over Current protect过流保护 | 1st Level Overcurrent Discharge 一级放电过流保护 | 30A±10A | ||
| Protect delay time 保护延迟时间 | 50ms—150ms | |||
| 2st Level Overcurrent Discharge 二级放电过流保护 | 60A±20A | |||
| Protect delay time 保护延迟时间 | 5ms—15ms | |||
| Protect relieve condition 保护解除条件 | Cut load | |||
| Overcurrent charge 充电过流保护 | 15A±5A | |||
| Protect delay time 保护延迟时间 | 500ms—1500ms | |||
| Balanced 平衡 | Balanced open voltage(Cell) 平衡开启电压 | 3.55V±0.050V | ||
| Balanced release voltage(Cell) 平衡释放电压 | 3.55V±0.050V | |||
| Balanced current(Cell) 平衡电流 | 55±10mA | |||
| Short Protection 短路保护 | Protect current 保护电流 | MIN200A | ||
| Detection delay time 检测延迟时间 | 100-600us | |||
| Recovery condition 短路保护恢复条件 | Cut short circuit .Cut load 断开负载.断开短路 | |||
| Dimension(L*W*T)尺寸 | 80*50*9mm | |||