Item 项目 |
Content 详细内容 |
Criterion 标准 |
Remarks备注 |
Over charge protect过充保护 | Over charge detection voltage(Cell) 单体过充保护电压 |
4.250V±0.025V | |
Protect delay time保护延迟时间 | 500ms—1500ms | ||
Over charge release voltage(Cell) 单体过充解除电压 |
4.150V±0.050V | ||
Over discharge protect过放保护 | Over discharge detection voltage(Cell) 单体过放保护电压 |
2.700V±0.080V | |
Protect delay time 保护延迟时间 |
50ms—150ms | ||
Over discharge release voltage(Cell) 单体过放解除电压 |
3.000V±0.080V | ||
Over Current protect 过流保护 |
Overcurrent Discharge 一级放电过流保护 |
8A±1A | |
Protect delay time 保护延迟时间 |
5ms—15ms | ||
Protect relieve condition 保护解除条件 |
Cut load断开负载 | ||
Balanced 平衡 |
Balanced open voltage(Cell) 平衡开启电压 |
4.200V±0.050V | |
Balanced release voltage(Cell) 平衡释放电压 |
4.200V±0.050V | ||
Balanced current(Cell) 平衡电流 |
62±10mA | ||
Short Protection 短路保护 |
Detection delay time 检测延迟时间 |
100-600us | |
Recovery condition 短路保护恢复条件 |
Cut short circuit . 断开负载.断开短路 |
||
Dimension(L*W*T)尺寸 | 65*60*1.2mm | ||