Item项目 | Content详细内容 | Criterion标准 | Remarks备注 |
Over charge protect过充保护 | Over charge detection voltage(Cell) 单体过充保护电压 |
4.300V±0.050V | |
Protect delay time 保护延迟时间 |
500mS—1500mS | ||
Over charge release voltage(Cell) 单体过充解除电压 |
4.150V±0.100V | ||
Over discharge protect过放保护 | Over discharge detection voltage(Cell) 单体过放保护电压 |
2.800V±0.050V | |
Protect delay time 保护延迟时间 |
50mS—300mS | ||
Over discharge release voltage(Cell) 单体过放解除电压 |
3.000V±0.100V | ||
Over Current protect过流保护 | over dischargeCurrent 放电过流 |
3.1-8A | |
over charge Current 充电过流 |
3.1-8A | ||
Protect delay time 保护延迟时间 |
5ms—50ms | ||
Protect relieve condition 保护解除条件 |
Cut load断开负载 | ||
Short Protection短路保护 | Protect condition 保护条件 |
External circuit short外部电路短路 | |
Detection delay time 检测延迟时间 |
200-500us | ||
Recovery condition 短路保护恢复条件 |
Cut short circuit 断开短路。断开负载 |
||
Dimension(L*W*T)尺寸 | 35.2*17.6*1.0mm | ||