Item项目 | Content详细内容 | Criterion标准 | Remarks备注 | |
Over charge protect过充保护 | Over charge detection voltage(Cell) 单体过充保护电压 |
3.700V±0.050V | ||
Protect delay time 保护延迟时间 |
500ms—1500ms | |||
Over charge release voltage(Cell) 单体过充解除电压 |
3.500V±0.050V | |||
Over discharge protect过放保护 | Over discharge detection voltage(Cell) 单体过放保护电压 |
2.300V±0.050V | ||
Protect delay time 保护延迟时间 |
500ms—1500ms | |||
Over discharge release voltage(Cell) 单体过放解除电压 |
/ | 充电恢复 | ||
Over Current protect过流保护 | 1st Level Overcurrent Discharge 一级放电过流保护 |
30A±10A | ||
Protect delay time 保护延迟时间 |
50ms—150ms | |||
2st Level Overcurrent Discharge 二级放电过流保护 |
60A±20A | |||
Protect delay time 保护延迟时间 |
5ms—15ms | |||
Protect relieve condition 保护解除条件 |
Cut load | |||
Overcurrent charge 充电过流保护 |
15A±5A | |||
Protect delay time 保护延迟时间 |
500ms—1500ms | |||
Balanced 平衡 |
Balanced open voltage(Cell) 平衡开启电压 |
3.55V±0.050V | ||
Balanced release voltage(Cell) 平衡释放电压 |
3.55V±0.050V | |||
Balanced current(Cell) 平衡电流 |
55±10mA | |||
Short Protection 短路保护 |
Protect current 保护电流 |
MIN200A | ||
Detection delay time 检测延迟时间 |
100-600us | |||
Recovery condition 短路保护恢复条件 |
Cut short circuit .Cut load 断开负载.断开短路 |
|||
Dimension(L*W*T)尺寸 | 80*50*9mm | |||