NO序号 | Items项目 | 保护条件 Protection condition |
保护延时时间 Delay time | 恢复条件 Release condition | |
1 | Cell Over charge voltage Cell 过压保护 | 1级保护 1st level safty | 4.250V±0.025V | 2.0s±0.5s | 4.100±0.050V |
2 | Cell Under discharge voltage Cell欠压保护 | 1级保护 1st level safty | 2.400V±0.025V | 2.0s±0.5s | 3.000±0.050V |
3 | Over current 过流保护 | OCC1 Threshold | 5.5A±0.2A | 5.0s±0.5s | 50mA/5s |
OCC2 Threshold | 6A±0.2A | 3.0s±0.5s | 50mA/5s | ||
OCD1 Threshold | 13.5A±0.2A | 5.0s±0.5s | 50mA/5s | ||
OCD2 Threshold | 15A±0.2A | 3.0s±0.5s | 50mA/5s | ||
AOLD Threshold | 16.6A±3.0A | 20ms-50ms | 0mA/10s | ||
ASCC Threshold | 22A±3.0A | 350uS-600us | 0mA/10s | ||
ASCD1 Threshold | 33A±3.0A | 200uS-600us | 0mA/10s | ||
ASCD2 Threshold | 33A±3.0A | 200uS-600us | 0mA/10s | ||
4 | Over temperature 温度保护 | OTC Threshold | 50±3℃ | 2.0s±0.5s | 40±3℃ |
OTD Threshold | 65±3℃ | 2.0s±0.5s | 55±3℃ | ||
OTF Threshold | 85±3℃ | 2.0s±0.5s | 55±3℃ | ||
UTC Threshold | -5±3℃ | 2.0s±0.5s | -0±3℃ | ||
UTD Threshold | -25±3℃ | 2.0s±0.5s | -20±3℃ | ||
5 | continuous current持续电流 | Charge current 充电电流 |
5A | ||
discharging current 放电电流 |
10A | ||||
6 | (L*W*H)PCB尺寸 | 120*45*1.0mm |