NO序号 | Items项目 | 保护条件 Protection condition |
保护延时时间 Delay time | 恢复条件 Release condition |
||
1 | Cell Over charge voltage Cell 过压保护 | 1级保护 1st level safty | 4.200V±0.025V | 2.0s±0.5s | 4.100±0.050V | |
2级保护 2nd level safty | - | - | - | |||
2 | Cell Under discharge voltage Cell 欠压保护 |
1级保护 1st level safty | 2.750V±0.025V | 2.0s±0.5s | 3.300±0.050V | |
3 | Over current 过流保护 |
OCC1 Threshold | 4A±0.2A | 4.0s±0.5s | -200mA/5s | |
OCC2 Threshold | 5A±0.2A | 2.0s±0.5s | -200mA/5s | |||
OCD1 Threshold | 6.5A±0.2A | 2.0s±0.5s | 200mA/10s | |||
OCD2 Threshold | 8A±0.2A | 1.0s±0.5s | 200mA/10s | |||
AOLD Threshold | 19.2A±3.0A | 20ms-40ms | 0mA/5s | |||
ASCC Threshold | 100A±5.0A | 350uS-600us | 0mA/5s | |||
ASCD1 Threshold | 100A±5.0A | 350uS-600us | 0mA/5s | |||
ASCD2 Threshold | 200A±5.0A | 350uS-600us | 0mA/5s | |||
4 | Over temperature 温度保护 | OTC Threshold | 60±3℃ | 5.0s±0.5s | 45±3℃ | |
OTD Threshold | 65±3℃ | 5.0s±0.5s | 55±3℃ | |||
OTF Threshold | 90±3℃ | 2.0s±0.5s | 65±3℃ | |||
UTC Threshold | 0±3℃ | 2.0s±0.5s | 3±3℃ | |||
UTD Threshold | -20±3℃ | 2.0s±0.5s | -10±3℃ | |||
5 | continuous current 持续电流 |
Charge current | 3A | |||
discharging current | 4A | |||||
6 | (L*W*H)尺寸 | 64*34*1.2mm |