NO序号 | Items项目 | 保护条件Protection condition | 保护延时时间 Delay time | 恢复条件 Release condition | ||
1 | Cell Over charge voltage Cell 过压保护 | 1级保护 1st level safty | 4.25V±0.025V | 2.0s±0.5s | 4.100±0.050V | |
2级保护 2nd level safty | 4.500V±0.050V | 6.0s±0.5s | 永久性损坏 permanent fail | |||
2 | Cell Under discharge voltage Cell欠压保护 | 1级保护 1st level safty | 2.500V±0.025V | 2.0s±0.5s | 3.000±0.050V | |
3 | Over current 过流保护 | OCC1 Threshold | 5A±0.2A | 3.0s±0.5s | -50mA/5s | |
OCC2 Threshold | 6A±0.2A | 2.0s±0.5s | -50mA/5s | |||
OCD1 Threshold | 11A±0.2A | 3.0s±0.5s | 0mA/10s | |||
OCD2 Threshold | 12A±0.2A | 2.0s±0.5s | 0mA/10s | |||
AOLD Threshold | 27A±3.0A | 10ms-30ms | 0mA/5s | |||
ASCC Threshold | 54.00A±5.0A | 350uS-600us | 0mA/5s | |||
ASCD1 Threshold | 54.0A±5.0A | 800uS-1000us | 0mA/5s | |||
ASCD2 Threshold | 66A±5.0A | 300uS-600us | 0mA/5s | |||
4 | Over temperature 温度保护 | OTC Threshold | 60±3℃ | 2.0s±0.5s | 55±3℃ | |
OTD Threshold | 65±3℃ | 2.0s±0.5s | 60±3℃ | |||
OTF Threshold | 90±3℃ | 2.0s±0.5s | 80±3℃ | |||
UTC Threshold | -5±3℃ | 2.0s±0.5s | -0±3℃ | |||
UTD Threshold | -25±3℃ | 2.0s±0.5s | -20±3℃ | |||
5 | continuous current持续电流 | Charge current 充电电流 |
4.0A | |||
discharging current 放电电流 |
5.0A | |||||
6 | (L*W*H)尺寸 | 64*34*1.2mm |