NO序号 | Items项目 | 保护条 件Protection condition | 保护延时时间 Delay time | 恢复条件 Release condition | ||
1 | Cell Over charge voltage Cell 过压保护 | 1级保护 1st level safty | 4.250V±0.025V | 2.0s±0.5s | 4.150±0.050V | |
2 | Cell Under discharge voltage Cell欠压保护 | 1级保护 1st level safty | 2.400V±0.025V | 2.0s±0.5s | 3.000±0.050V | |
3 | Over current 过流保护 |
OCC1 Threshold | 6A±0.2A | 4.0s±0.5s | -200mA/5s | |
OCC2 Threshold | 7A±0.2A | 2.0s±0.5s | -200mA/5s | |||
OCD1 Threshold | 7A±0.2A | 2.0s±0.5s | 200mA/10s | |||
OCD2 Threshold | 8A±0.2A | 1.0s±0.5s | 200mA/10s | |||
AOLD Threshold | 30.5A±5.0A | 20ms-50ms | 0mA/15s | |||
ASCC Threshold | 55A±5.0A | 300uS-1000us | 0mA/5s | |||
ASCD1 Threshold | 55A±5.0A | 600uS-1200us | 0mA/5s | |||
ASCD2 Threshold | 66A±5.0A | 200uS-600us | 0mA/5s | |||
4 | Over temperature 温度保护 |
OTC Threshold | 60±3℃ | 5.0s±0.5s | 55±3℃ | |
OTD Threshold | 65±3℃ | 5.0s±0.5s | 60±3℃ | |||
OTF Threshold | 90±3℃ | 2.0s±0.5s | 80±3℃ | |||
UTC Threshold | -5±3℃ | 2.0s±0.5s | -2±3℃ | |||
UTD Threshold | -25±3℃ | 2.0s±0.5s | -20±3℃ | |||
5 | Charge Balanced 充电平衡 |
Cell Balance Threshold | 3.600±0.050V | |||
平衡开始电压 | ||||||
Balanced Cell Balance Window | 100mV | |||||
平衡压差启动电压 | ||||||
Cell Balance Min平衡最小电压 | 40mV | |||||
Cell Balance Interval 平衡间隔时间 | 20s | |||||
6 | continuous current 持续电流 |
Charge current | 5.0A | |||
充电电流 | ||||||
discharging current | 5.0A | |||||
放电电流 | ||||||
7 | (L*W*H)尺寸 | 73.8*18.5*1.0mm |